"10 key points on High-Performance Liquid Chromatography (HPLC) troubleshooting" 1. Pressure Fluctuations Cause: Often caused by air trapped in the system, partially blocked filters, or poorly mixed solvents. Solution: Degas solvents, check for blockages, and ensure proper mixing. 2. Baseline Noise Cause: Could be due to a dirty detector, improper mobile phase preparation, or electrical interference. Solution: Clean the detector cell, use high-quality solvents, and eliminate any electrical noise sources. 3. Peak Tailing Cause: Poor column performance, loose fittings, interaction of analytes with active sites on the stationary phase, or incorrect pH of the mobile phase. Solution: Regenerate or replace the column, or adjust the pH of the mobile phase to improve peak shape. 4. Retention Time Drift Cause: Fluctuations in temperature, inconsistencies in mobile phase composition, or column degradation. Solution: Maintain stable temperature and mobile phase composition; replace the column if necessary. 5. Ghost Peaks Cause: Contamination of the system, improper gradient conditions, or issues with sample preparation. Solution: Perform thorough system cleaning, optimize gradient methods, and ensure proper sample preparation. 6. Low Sensitivity Cause: Detector issues, dirty or degraded column, or incorrect mobile phase pH. Solution: Check detector settings, replace the column, and optimize the mobile phase. 7. Clogged Columns Cause: Sample particulate matter or precipitated mobile phase. Solution: Filter all samples and solvents, and backflush the column if compatible. 8. Split Peaks Cause: Can be due to a partially blocked injector, poor sample solubility, or column overload. Solution: Clean the injector, dissolve samples in the mobile phase, and ensure proper sample concentration. 9. Broad Peaks Cause: Column aging, improper mobile phase composition, or sample overloading. Solution: Replace the column, optimize the mobile phase, and reduce the sample volume or concentration. 10. Leaky System Cause: Loose fittings, worn seals, or damaged tubing. Solution: Tighten fittings, replace seals, and inspect tubing for damage. Reference: 1. Snyder, L. R., Kirkland, J. J., & Glajch, J. L. (1997). Practical HPLC Method Development. John Wiley & Sons. 2. McMaster, M. C. (2007). HPLC: A Practical User’s Guide. John Wiley & Sons. 3. Kazakevich, Y., & LoBrutto, R. (2007). HPLC for Pharmaceutical Scientists. John Wiley & Sons. 4. Swartz, M. E., & Krull, I. S. (2012). Analytical Method Development and Validation. CRC Press. 5. Meyer, V. R. (2010). Practical High-Performance Liquid Chromatography. John Wiley & Sons.
Analytical Chemistry Tools
Explore top LinkedIn content from expert professionals.
-
-
Glass Transition Temperature (Tg) - A Key to Material Behaviour! Ever noticed how a plastic component can become brittle in cold weather or more pliable when heated? This phenomenon is often governed by the Glass Transition Temperature (Tg), a key property for understanding amorphous materials, especially polymers. 🔍 Deep Dive into Tg: Tg isn't a sharp melting point like in crystalline materials. Instead, it's a temperature range where an amorphous solid transitions from a rigid, glassy state (below Tg) to a more flexible, rubbery state (above Tg). This transition reflects the onset of cooperative molecular motion. Below Tg, polymer chains have limited movement, while above, they gain enough energy to slide past each other. 🔬 Why Tg Matters in Real-World Applications: Performance Optimization: Knowing Tg helps predict how materials will behave under varying temperatures, crucial for applications ranging from automotive parts to medical devices. Manufacturing Precision: Tg dictates processing conditions like molding temperatures and annealing cycles, ensuring product quality and consistency. Material Selection: Engineers use Tg to select materials that meet specific temperature requirements, preventing failures and enhancing product longevity. 🛠️ Advanced Techniques for Tg Determination: Differential Scanning Calorimetry (DSC): Measures heat flow differences, revealing the subtle energy changes associated with the glass transition. It’s excellent for routine analysis and comparing materials. Dynamic Mechanical Analysis (DMA): Applies oscillating forces, measuring the material’s viscoelastic response. This technique is highly sensitive to molecular relaxations and provides insights into storage and loss moduli. Thermomechanical Analysis (TMA): Tracks dimensional changes with temperature, revealing thermal expansion and contraction behaviour. This is valuable for predicting dimensional stability and identifying Tg through changes in the expansion coefficient. 💡 Key Factors Influencing Tg: Polymer Architecture: Molecular weight, branching, and crosslinking density significantly impact chain mobility and, therefore, Tg. External Factors: Heating/cooling rates, plasticizers, and even ambient moisture can shift the observed Tg, highlighting the importance of controlled testing environments. Composition: In copolymers or blends, the relative amounts of different components will greatly affect the final Tg value. Understanding Tg is vital for engineers, material scientists, and anyone involved in product development. By mastering this concept, we can design more robust, reliable, and innovative products. #materialscience #polymerscience #polymercharacterization #viscoelasticity
-
Which Detector Suits Your Analyte? In HPLC (High-Performance Liquid Chromatography), the detector you choose can make or break your analysis. With a wide range of detectors available, each type is tailored to different compound properties — making the selection a crucial step in method development. Here’s a breakdown of the main HPLC detectors and their optimal use cases: 📘 UV/Vis Detector ▪ Ideal for: Majority of organic analytes ▪ Principle: Detects based on UV absorbance 📘 PDA (Photodiode Array) ▪ Ideal for: Organic analytes with overlapping peaks ▪ Advantage: Scans multiple wavelengths simultaneously, enabling spectral purity analysis 📘 Fluorescence Detector ▪ Ideal for: Aromatic and highly conjugated compounds ▪ Notable for: High sensitivity for π→π* transitions and alicyclic carbonyl structures 📘 RID (Refractive Index Detector) ▪ Ideal for: Sugars and compounds with no UV absorbance ▪ Advantage: Universal detection (non-selective) 📘 ECD (Electrochemical Detector) ▪ Ideal for: Redox-active analytes like multivitamins ▪ Advantage: Very high sensitivity to electroactive compounds 📘 ELSD (Evaporative Light Scattering Detector) ▪ Ideal for: Non-volatile compounds or those with poor UV response ▪ Common in: Lipid, sugar, and polymer analysis 📎 Choosing the correct detector depends on your analyte’s characteristics — absorption, volatility, and chemical structure. 📊 Are you working with UV-active molecules, sugars, or redox-sensitive compounds? The right detection strategy makes all the difference in accuracy and sensitivity. 💬 What’s your go-to HPLC detector — and in what application? #HPLC #Chromatography #AnalyticalChemistry #PharmaceuticalScience #QualityControl #ResearchAndDevelopment #PDA #UVVis #Fluorescence #RID #ELSD #ECD #LabLife #ScienceCommunication
-
Infrared (#IR) spectroscopy is an #analytical_technique used to identify and study the chemical composition and molecular structure of substances based on their interaction with #infrared_light. The method relies on the principle that molecules absorb specific frequencies of infrared radiation, which leads to molecular #vibrations and #rotations. ✅ Principles of IR Spectroscopy Molecular Vibration: When infrared radiation is absorbed by a molecule, it can cause the bonds within the molecule to vibrate. These vibrations can be stretching (increasing or decreasing #bond_length) or bending (changing #bond_angles). ✔️ #Wavenumber: IR spectra are typically plotted as absorbance (or transmittance) versus wavenumber (measured in cm⁻¹), which is inversely related to wavelength. The wavenumber indicates the energy of the vibrations. ✔️ #Functional_Groups: Different functional groups (e.g., –OH, –NH, –C=O, –C–H) have characteristic absorption bands in the IR spectrum. By identifying these bands, chemists can deduce the presence of specific functional groups within a compound. ✅ Instrumentation ▪️ #IR_Source: A source of infrared radiation, such as a nichrome wire or a Globar (silicon carbide) source. ▪️ #Sample_Holder: Samples can be analyzed in various forms, including solid, liquid, or gas. Common methods include using #KBr pellets for solids or liquid cells for liquids. ▪️ #Detector: Common detectors include thermocouples, pyroelectric detectors, and photoconductive detectors, which measure the intensity of transmitted or absorbed IR light. ✅ Types of IR Spectroscopy ✔️ #Transmission_IR_Spectroscopy: The sample is placed in the path of IR radiation, and the transmitted light is measured. ✔️ #Attenuated_Total_Reflectance (#ATR) #Spectroscopy: A technique that allows for direct analysis of solid or liquid samples without extensive preparation. The sample is placed in contact with a crystal, and IR light is reflected at the interface, allowing for analysis. ✔️ #Fourier_Transform_IR (#FTIR) Spectroscopy: A modern technique that collects all wavelengths simultaneously and uses a #Fourier transform to convert time-domain data into frequency-domain spectra. FTIR is faster and more sensitive than traditional methods. ✅ Limitations ▪️ #IR_spectroscopy cannot provide information about the molecular weight or the elemental composition of a compound. ▪️ Overlapping #peaks can make interpretation challenging, and complex mixtures may require additional techniques for clarification. Overall, IR spectroscopy is a powerful tool in chemical analysis, providing valuable information about molecular structure and functional groups in a wide range of applications.
-
Amplifying the Language of Life: PCR, qPCR & RT-PCR 🧬⚡️ From detecting deadly viruses to tracking gene expression — these techniques have revolutionized modern molecular biology! Let’s dive into the 🔬 molecular magic of three closely related but uniquely powerful tools: 🔁 PCR (Polymerase Chain Reaction) Invented by Kary Mullis in 1983 — a Nobel-winning innovation! PCR allows us to amplify a specific DNA segment into millions of copies in just a few hours. 🧪 Components: • DNA Template • Primers • DNA Polymerase (e.g., Taq) • dNTPs • Buffer 🔥 Steps: 1️⃣ Denaturation 2️⃣ Annealing 3️⃣ Extension ➡️ Result: Billions of DNA copies! 📊 qPCR (Quantitative PCR / Real-Time PCR) Think PCR, but with a smart twist: it monitors amplification in real-time. Used for quantification of nucleic acids — in virology, oncology, and diagnostics. 💡 Uses fluorescent dyes (e.g., SYBR Green) or probes (e.g., TaqMan) to detect and quantify DNA as it amplifies. ✨ Output: Amplification curves, CT values, melt curves. 🔄 RT-PCR (Reverse Transcription PCR) Want to study RNA? Start here. RT-PCR converts RNA → cDNA using reverse transcriptase, then amplifies it like standard PCR. ✅ Widely used for gene expression analysis, viral RNA detection (e.g., SARS-CoV-2). When combined with qPCR = RT-qPCR — a gold standard in molecular diagnostics. 💡 Why It Matters: • Diagnose diseases early 🧫 • Quantify gene expression 🔍 • Track mutations & pathogens 🦠 • Fuel personalized medicine 💊 • Support forensic, agricultural & environmental sciences 🌱⚖️ From basic research to bedside diagnostics — PCR, qPCR, and RT-PCR are the unsung heroes behind the scenes. Let’s keep amplifying knowledge and decoding life — one reaction at a time!
-
XRD (X-ray diffraction) peaks provide key information about the crystalline structure of a material. The peak positions on the X-axis (2θ angle) correspond to specific atomic plane spacings (d-spacings) in the crystal lattice, as described by Bragg's law. The intensity (height or area) of the peaks reflects the abundance of atoms in those planes and their crystal orientation. The width of the peaks reveals crystal size and defects: narrower peaks indicate larger crystal size and higher crystallinity, while broader peaks suggest smaller crystals, structural defects, or amorphous nature. The full XRD pattern can be matched against reference databases to identify phases and compounds. Images of XRD patterns typically show peaks at specific 2θ values where constructive interference occurs. For example, with crystalline materials, sharp peaks appear, whereas amorphous materials produce broad humps. The relative intensity of peaks helps determine phase composition and texture. Here are useful visual insights from typical XRD peak images: Sharp, narrow peaks indicate larger, well-ordered crystalline domains. Broad peaks indicate smaller crystallite sizes or defects. Peak intensity variations correspond to abundance and orientation of crystal planes. Peak positions correspond to specific atomic spacing, thus identifying crystal structure. These concepts are visualized in the XRD patterns below where peak position, intensity, and width convey crystallographic information about the sample.
-
𝟵𝟬% 𝗼𝗳 𝗱𝗿𝘂𝗴𝘀 𝗳𝗮𝗶𝗹 𝗰𝗹𝗶𝗻𝗶𝗰𝗮𝗹 𝘁𝗿𝗶𝗮𝗹𝘀. Despite rigorous testing, the pharmaceutical industry continues to grapple with a high failure rate. It’s a decades old problem that persists. The disconnect between animal models and human biology has led to inefficiencies and ethical concerns. It’s a moral tug-of-war that once seemed unresolvable medical progress often came at the cost of animal welfare. More than 115 million animals are estimated to be used in drug testing globally each year. Shockingly, 95% of drugs shown to be safe and effective in animal tests fail in human trials. And nearly 99% of animals used in scientific experiments are not protected by federal animal welfare laws. 𝗦𝗼 𝗵𝗼𝘄 𝗱𝗼 𝘄𝗲 𝗱𝗲𝘃𝗲𝗹𝗼𝗽 𝘀𝗮𝗳𝗲, 𝗲𝗳𝗳𝗲𝗰𝘁𝗶𝘃𝗲 𝗱𝗿𝘂𝗴𝘀 𝗳𝗼𝗿 𝗵𝘂𝗺𝗮𝗻𝘀 𝘄𝗶𝘁𝗵𝗼𝘂𝘁 𝗿𝗲𝗹𝘆𝗶𝗻𝗴 𝗵𝗲𝗮𝘃𝗶𝗹𝘆 𝗼𝗻 𝗮𝗻𝗶𝗺𝗮𝗹 𝘁𝗲𝘀𝘁𝗶𝗻𝗴? Scientists at Harvard University introduced a groundbreaking idea: creating replicas of human organs on tiny lab chips. Just as we’ve downsized from massive storage units to microchips in our devices, could we now miniaturize organs onto chips? I was thrilled to read about this development. I’ve often wondered about the moral cost of inducing disease in other living beings for the sake of our health. 𝗢𝗿𝗴𝗮𝗻𝘀-𝗼𝗻-𝗰𝗵𝗶𝗽𝘀 (𝗢𝗼𝗖𝘀) are essentially tiny 3D cell cultures that act as a bridge between traditional animal testing and the complexities of human biology. OoC models consist of miniature tissue systems grown within microfluidic chips, lined with living human cells. These chips simulate human physiology, enabling drug development, disease modelling, and personalized medicine. With OoCs, researchers can create more accurate and efficient models for testing human drugs reducing the likelihood of ineffective or harmful treatments. By mimicking a cell’s microenvironment on a chip, we can study genetic factors, explore new treatment avenues for complex conditions, and even address rare diseases with limited sample sizes. OoCs also enable biomaterial testing, helping evaluate the biocompatibility of materials used in medical devices. Recently, a firm called 𝗘𝗺𝘂𝗹𝗮𝘁𝗲 tested a Liver-on-a-Chip device with 27 drugs that had passed animal trials but were toxic to humans. The chip accurately flagged 87% of these harmful compounds. I'm truly excited about the integration of tissue engineering and microfabrication to advance our understanding of human biology ethically and effectively. I hope to see a future where research and commercial applications in this space grow rapidly, helping us build a more humane and progressive health tech ecosystem one where millions of animals no longer have to suffer in the name of human progress. Watch this video by Harvard to learn more. #healthcare #technology #healthtech #innovation
-
Terminologies in Chromatography 1. Retention Time (tR) Time taken by an analyte to travel from injector to detector. Each analyte has a unique retention time. Used for qualitative identification. Qualification: Must be consistent with standard (within ±2%). 2. Dead Time (t₀) Time taken by a completely unretained compound to elute. Indicates void volume. Used to calculate the capacity factor (k’). 3. Capacity Factor (k’) Formula: k’ = (tR - t₀)/t₀ Shows analyte retention relative to void volume. Qualification: 1 < k’ < 10 for optimal separation. 4. Peak Area & Peak Height Used for quantification. Peak area is directly proportional to analyte concentration. Qualification: Reproducibility within ±2% RSD across replicates. 5. Theoretical Plates (N) Formula: N = 16*(tR/W) 2 Measures column efficiency. Qualification: Must meet column manufacturer’s specification or method validation criterion. 6. Resolution (Rs) Formula: Rs = (tR2 - tR1)/0.5(W1 + W2) Indicates peak separation. Qualification: Rs > 1.5 for baseline separation. 7. Tailing Factor (T) Formula: T = W0.05 / 2f Assesses peak symmetry. Qualification: Ideal T ≈ 1. Acceptable ≤ 2. 8. Selectivity (α) Formula: α = k’2 / k’1 Describes separation between two compounds. α > 1 is required. 9. Detector Response Factor (RF) Formula: RF = Area / Concentration Used in external standard methods. Qualification: RF should be consistent across replicates. 10. Internal Standard Method Corrects variability in injection or matrix. Qualification: %RSD of analyte/IS area ratio ≤ 2%. 11. Linearity (r²) Measures fit of calibration curve. Qualification: r² ≥ 0.999 over working range as per ICH Q2(R1). 12. System Suitability Parameters Includes retention time consistency, %RSD of area/RT (≤ 2%), tailing factor (≤ 2), theoretical plates (N), resolution (Rs > 1.5). Must be met before sample analysis starts. 13. LOD & LOQ LOD (Limit of Detection): Minimum detectable amount, not quantifiable. LOQ (Limit of Quantification): Lowest amount quantifiable with precision. Calculation: LOD = 3.3×(SD/Slope), LOQ = 10×(SD/Slope) Qualification: LOQ must be validated with %RSD ≤ 10% and accuracy within 80–120%. 14. Baseline Noise & Drift Noise affects detection limits; drift indicates system instability. Qualification: Baseline noise < 10% of smallest analyte peak height. Drift < 2% over run time. 15. Integration Parameters Ensure consistent integration settings (threshold, peak width). Qualification: Consistent area results across replicates. 16. Standard Deviation (SD) Measures variation from the mean. Qualification: Used in precision assessment. 17. %RSD Relative standard deviation. Formula: %RSD = (SD/mean)×100 Qualification: ≤ 2% in SST and precision studies. 18. Coefficient of Determination (R²) Indicates how well calibration data fits regression model. Qualification: r² ≥ 0.999.
-
✔ HPLC Technique Explanation HPLC (short for High-Performance Liquid Chromatography) is an analytical technique used for the separation, identification, and quantification of chemical compounds in a mixture. It is a fundamental tool in analytical chemistry and is widely applied in fields such as pharmaceuticals, food, biochemistry, and environmental science. ✔ Principle of HPLC: The technique relies on liquid chromatography, where compounds are separated based on their solubility or interaction between two main phases: Stationary Phase: A solid material or small particles inside the chromatographic column that remain fixed. Mobile Phase: A liquid that flows through the stationary phase, carrying the sample to be analyzed. Working Steps: Sample Preparation: The material to be analyzed is dissolved in a suitable solvent. Injection: The sample is injected into the system through a specific unit. Separation: The mobile phase flows through the column containing the stationary phase. The different components of the sample are separated based on their interactions with the stationary phase. ✔ Detection: The separated components are detected using a suitable detector, such as: UV detector. Conductivity detector. Fluorescence detector. ✔ Analysis: Results are typically displayed as a chromatogram (a graph) where each peak represents a specific compound, with the retention time and signal intensity providing information about the compound. ✔ Advantages of HPLC: High precision in separation and analysis. Capability to analyze complex mixtures. Suitable for small sample quantities. Ideal for analyzing heat-sensitive compounds, such as proteins. ✔ Applications of HPLC: Pharmaceutical Industry: For analyzing active ingredients in drugs. Food Industry: To detect contaminants or food components. Biochemistry: For separating proteins, amino acids, and hormones. Environmental Science: For analyzing pollutants in water or air. ✔ Types of HPLC Columns: Reversed-Phase HPLC Columns: The most commonly used type. Normal-Phase HPLC Columns. Ion-Exchange HPLC Columns. Size Exclusion HPLC Columns. #HPLC #Separation_method #Chemical_analysis #Chemistry
-
Spectroscopy: The Science of Light-Matter Interaction Spectroscopy is more than just an analytical tool—it’s a gateway to understanding matter at the atomic and molecular level. By studying how electromagnetic radiation interacts with substances, we can decode valuable information about their composition, structure, and electronic properties. 🔹 The Fundamental Mechanism of Spectroscopy At its core, spectroscopy involves: 1️⃣ Absorption, Emission, or Scattering of Light – When light (electromagnetic radiation) interacts with matter, certain wavelengths are absorbed, emitted, or scattered depending on the material's energy states. 2️⃣ Energy Transitions – Electrons, molecules, or nuclei transition between energy levels when they absorb or emit photons. These transitions are governed by quantum mechanics. 3️⃣ Spectral Analysis – The resulting spectrum—a unique fingerprint of the substance—is analyzed to determine structural and compositional details. 🔹 Key Components of a Spectroscopic System A typical spectroscopic setup includes: 📌 Radiation Source – Provides the necessary electromagnetic waves (e.g., UV lamp, laser, X-ray tube). 📌 Monochromator or Dispersive Element – Filters and selects specific wavelengths (e.g., prisms, diffraction gratings). 📌 Sample Holder – The medium where light interacts with the analyte (e.g., cuvettes, fiber optics). 📌 Detector – Converts light signals into readable data (e.g., photomultiplier tubes, charge-coupled devices). 📌 Data Processing System – Analyzes the intensity and wavelength of absorbed/emitted radiation to interpret results. 🔹 Types of Spectroscopy & Industrial Applications 🔸 UV-Visible Spectroscopy (UV-Vis) – Quantifies concentration based on electronic transitions; used in pharmaceuticals and environmental monitoring. 🔸 Infrared Spectroscopy (IR & FTIR) – Identifies molecular vibrations; widely applied in polymer, food, and forensic sciences. 🔸 Raman Spectroscopy – Studies molecular vibrations via inelastic scattering; critical in material science and nanotechnology. 🔸 Nuclear Magnetic Resonance (NMR) Spectroscopy – Explores atomic environments using nuclear spin properties; essential in organic chemistry and drug discovery. 🔸 X-ray Spectroscopy (XRF, XPS) – Analyzes elemental composition and oxidation states; crucial for metallurgy and semiconductor research. With advances in AI-powered spectral analysis and portable spectrometers, spectroscopy is evolving beyond the lab, making real-time diagnostics and in-field chemical analysis more accessible than ever. Have you used spectroscopy in your industry? What challenges or breakthroughs have you encountered? Let’s discuss in the comments! 👇 #spectroscopy #ndt #ndtanalysis #engineering #technology #quality #qa #qc #materialanalysis